SAT Systems was established in 1984
Sub Aquatic Technical Systems Ltd - Gas Analysis, Monitoring and Control - Data Logging and Communications offering Diving and Hyperbaric Solutions

Tuesday, March 19, 7:59 am

Series-5 *New Range of instrumentation

SAT-5
Air-5

Wire length Counter

Wire Length Counter

Description

The SAT-5 Wire Length Counter uses the signal from a shaft encoder or pair of proximity sensors fitted to a sheave to measure wire length.  The display is scaled in Metres or Feet. Metric or imperial distance units can then be selected without re-calibration. Typical applications include monitoring LARS and other winches. One of the features is the ability to set and measure distance from a marker, which is useful when positioning a clump weight. The counter has high and low alarms with relay output and an Ethernet interface for data recording. The instrument also includes non-volatile recording of the display readings, alarms and calibrations.

Specifications

Order Code : C01-009-011-01-x-y*

Model Number : SAT-5 Wire length

Range : 1000 Metres / 3500 Feet

Resolution : 0.1 metres / 0.1 Feet

Input : NPN or PNP type proximity sensors

Alarms : High & Low

Relay output : 6A Change Over Relay

Data Logging Output : Ethernet

Power Requirements : 110 – 220 VAC 50/60Hz or 10-36VDC(5W)

Operating Temperature : 0 to +50 °C

Storage Temperature : -20 to +60 ºC

Housing (Sub-rack Module) : 3U x 21 HP x 210mm including leads

Weight : 1.3Kg

Approvals : EN61326-1:2013 Group 1, Class A EN61010-1:2010

RoHS : Yes

*‘x’ & ‘y’ to be substituted for numbers, which denote options and power supply types. Please enquire for more details.

Request Quotation
Request a Quotation

Thank you for your interest in receiving a Quotation for our instrumentation.


Below you will find three short steps to follow in order for us to produce a quotation. To enable us to deal with your request efficiently, please ensure that you supply your full Company details together with your exact requirements.

Please note: all quotations are manually generated based on the information you will supply. Details of your intended supply voltage (if applicable) will ensure we supply the correct product code and lead time.
step 1 step 2 step 3
Please register on our Helpdesk, supplying your full company details Please check the email account that you used when registering, we have sent you an email with a link to activate your account Once your account is activated - Login to our helpdesk and select Request and Quotation
Please Click Here To Register Now! If you do not receive our activation email or experience any problems registering, please Contact Us and we will manually create your account. Login To Our Helpdesk Now!

Data Sheets

Please use the form below to request data sheets for our New Series-5 Range of instrumentation.

Please Note: All data sheets are sent manually to the email address you supply - requests can take up to 48 hours to complete and are handled during our normal office hours.

Thank You


Data Sheet Request Form

Data Sheets




























S.A.T.Systems Ltd   1 Kelly Industrial Estate, Kirk Michael, Isle of Man,  IM6 1SS