The SAT-5 Oxygen partial pressure monitor uses an electro-chemical oxygen sensor connected to a 4-20mA transmitter with local display that is located inside the pressure compartment to be monitored. The transmitter connects to the surface display unit using a single twisted screened pair cable.
The monitor will display oxygen levels are in the range of 0 – 2.000 bar with one millibar resolution. The monitor has a history page that will display a graph of oxygen partial pressure against time with selectable time spans of between 20 minutes and 24 hours.
An internal “black box” recorder stores 12 months’ worth of data including user interactions on a micro SD card; this feature provides a useful audit trail.
Ethernet and isolated 4-20mA output connections are fitted as standard to interface the instrument with data visualisation and storage software.
The SAT-5 instruments are fully configurable from their touch screen user interface. Important settings are password protected to prevent unauthorised adjustment.
This instrument is suitable for remote monitoring of oxygen partial pressure typically in diving bells and SPHLs where the sensor is located a long distance from the primary display.
Size / Weight:
Property | Value |
Length | 210 mm |
Width | 106 mm |
Height | 128 mm |
Weight | 1.3 kg |
Temperature Range:
Property | Value |
Operating | 0 – 50 ºC |
Storage | -20 – 60 ºC |
Other:
Property | Value |
RoHS Compliant | Yes |
Electrical Specifications
Mains Power Input:
Property | Value |
Voltage | 100 – 240 V |
Frequency | 50 / 60 Hz |
Power | 5 W |
Optional DC Power Input:
Property | Value |
Voltage | 10 – 36 V |
Power | 5 W |
Relays:
Property | Value |
Maximum voltage | 250 VAC |
Maximum current | 6 A |
Volt-free contacts | Yes |
4-20mA Output:
Property | Value |
Maximum load | 600 Ω |
Drive voltage | 15 V |
Galvanic Isolation | Yes |
Isolation voltage | 400 Vrms |
Alarms:
Property | Value |
Loudness | 76 dB @ 1m |
Sensor Specifications
Chemical oxygen sensor:
Property | Value |
Part number | D-05 |
Lifetime | ~5,000,000 mbar-hours, ~2.5years at 0.209 bar |
Range | 0 – 2 bar |
Accuracy | ± 5 mbar |
Response Time T90 | <14s |
4-20mA Oxygen transmitter:
Property | Value |
Part number | B03-35-01 |
Lifetime | ~5,000,000 mbar-hours, ~2.5years at 0.209 bar |
Range | 0 – 2 bar |
Accuracy | ± 5 mbar |
Response Time T90 | <14s |
Thank you for your interest in receiving a Quotation for our instrumentation. |
||
Please register on our Helpdesk, supplying your full company details | Please check the email account that you used when registering, we have sent you an email with a link to activate your account | Once your account is activated - Login to our helpdesk and select Request and Quotation |
Please Click Here To Register Now! | If you do not receive our activation email or experience any problems registering, please Contact Us and we will manually create your account. | Login To Our Helpdesk Now! |
Please use the form below to request data sheets for our New Series-5 Range of instrumentation.
Please Note: All data sheets are sent manually to the email address you supply - requests can take up to 48 hours to complete and are handled during our normal office hours.
Thank You